Why does mixed bed conductivity rise after a few weeks?
Usually sodium leaking through the cation component, or CO₂ loading the anion component from an upstream fault. Check regeneration and the cation-to-anion ratio before replacing resin.
Why does conductivity rise in a mixed bed?
Conductivity measures ions in the water, so anything that leaves an ion behind shows up immediately. In a mixed bed the usual suspects are sodium slipping through the cation beads, carbon dioxide loading the anion beads, or organics coating both.
The order matters: check the cheapest cause first. Regeneration records and the upstream train cost nothing to inspect, while a resin replacement costs a charge and a shutdown.
How do you prove it is a sodium leak?
Measure sodium specifically rather than conductivity alone. A sodium analyser on the outlet will show a few µg/L while conductivity has barely moved — that is the signature of a cation component that is exhausted or badly regenerated.
If sodium is the cause, the cation-to-anion ratio is the next thing to check. A bed that has lost anion resin — through carry-over or a bad transfer — behaves like a cation bed with the anion missing.
What role does CO₂ play?
Carbon dioxide dissolves to carbonic acid and loads the anion resin. If the upstream two-bed train is not removing CO₂ properly, the mixed bed absorbs it and the anion component exhausts early, even though the cation side is fine.
That is why a mixed bed behind a poorly regenerated anion bed fails predictably at the same throughput every cycle. Fix the upstream regeneration, and the polish bed recovers.
Which regeneration mistakes cause it?
Caustic that is too dilute, too cold, or contaminated with carbonate leaves anion sites partly exhausted. So does a separation step that lets caustic reach cation resin, and transfer water that carries hardness into the bed.
On site, the two most common are caustic temperature below 40 °C on a Type I bed, and mixing that is too short to re-blend the bed after regeneration.
When is it actually the resin?
Single-use cartridge polishers are designed to exhaust and be thrown away; there the resin is the answer, and the only decision is how often to replace the charge.
On a regenerable mixed bed, resin is the cause only when capacity tests show a real loss. Age alone is not a diagnosis — check the regeneration record first, and replace only when the numbers say so.