Container loading from Xingang (Tianjin), Qingdao and Shanghai — Lianyungang, Jiangsu, China

Ion exchange glossary

The words that appear on a resin datasheet, in a water analysis, and in every quotation — defined in one sentence each, the way a plant engineer uses them.

In one line: if two suppliers quote different capacities, check the unit first — mmol/mL is volumetric and sizes the vessel, mmol/g is gravimetric and only compares chemistry.

34 terms

Resin, water and paperwork

Grouped roughly the way a project runs: what the resin is, how it is measured, how it is run, and what travels with it.

Definitions
Anion exchange resinA resin with positively charged fixed groups that exchanges anions such as chloride, sulfate and silicate. Regenerated with sodium hydroxide.
Cation exchange resinA resin with negatively charged fixed groups that exchanges cations such as calcium, magnesium and sodium. Regenerated with brine or acid.
Strong acid cation (SAC)Sulfonic acid resin that removes all cations regardless of the associated anion. Used for softening and as the cation stage of demineralization.
Weak acid cation (WAC)Carboxylic acid resin that removes only the cations bound to alkalinity. High capacity, cheap regeneration, and no effect on neutral salts.
Strong base anion (SBA)Quaternary ammonium resin, Type I or Type II. The only family that removes weakly ionised silica and carbon dioxide.
Weak base anion (WBA)Tertiary amine resin that absorbs strong mineral acids. High capacity and cheap regeneration, but it cannot remove silica or CO2.
Gel resinA dense polymer network swollen with water, with no permanent pores. Higher volumetric capacity; less tolerant of organics and oxidants.
Macroporous resinA bead with a permanent pore structure of 20–100 nm, typically 20–50 m²/g of surface area. Lower capacity, far better fouling resistance and kinetics.
Mixed bedA homogeneous blend of cation and anion resin in one vessel, used to polish demineralised water to below 0.1 µS/cm.
Chelating resinA resin with iminodiacetic or aminophosphonic groups that binds heavy metals by coordination. Selective even in hard water.
Adsorbent resinA macroporous polymer with no functional groups. Removes colour and organics by adsorption, not by ion exchange.
Volumetric capacityExchange capacity per litre of wet resin, usually in mmol/mL or eq/L. The number to size a vessel with — it tells you how long a bed runs.
Gravimetric capacityExchange capacity per gram of dry resin, in mmol/g. Useful for comparing chemistry, not for sizing a vessel.
Moisture contentWater held inside a fully swollen bead, as a percentage of wet weight. A rise against the original certificate suggests oxidation or fouling.
Bulk densityMass of wet resin per unit volume as packed, typically 650–850 g/L. Used to convert a resin volume into a shipping weight and bag count.
Effective bead sizeThe sieve size at which 10 % of the beads are smaller, in mm. 0.40–0.70 mm covers most softening and demineralization.
Uniformity coefficientThe ratio of the 60 % to the 10 % bead size. At 1.60 or below, the bed classifies cleanly and the pressure drop stays predictable.
Crosslink (DVB)Divinylbenzene content, written in the model number — 001×7 contains 7 % DVB. More crosslink means lower moisture, slower kinetics and less swelling.
SwellingVolume change when the resin changes ionic form, for example Na+ to H+. Large swelling needs freeboard or the bed lifts the distributor.
EBCTEmpty bed contact time — bed volume divided by flow rate. Softening 2–6 minutes, demineralization 2–5 minutes, mixed beds 1–2 minutes.
Service flow rateThe flow per unit of bed cross-section, in m/h or bed volumes per hour. It sets the pressure drop and the risk of channeling.
BreakthroughThe point at which the ion being removed first appears in the outlet. Run length is measured to breakthrough, not to exhaustion.
LeakageIons still present in the outlet after regeneration. It follows the regeneration dose and the bed depth, not the resin quantity.
RegenerationRestoring the exchange sites with brine, acid or caustic. Efficiency is the fraction of the regenerant actually used by the bed.
BrineSodium chloride solution used to regenerate sodium-cycle cation resin, typically 8–10 % and 100–150 g per litre of resin.
AttritionLoss of whole beads through mechanical wear, osmotic shock and thermal cycling. Measured as an attrition or whole-bead rate, not as capacity.
FinesFragments smaller than the specified bead size, produced by attrition. They raise pressure drop and blind downstream filters.
HardnessCalcium and magnesium content, expressed as mg/L CaCO3 or meq/L. 1 meq/L equals 50 mg/L as CaCO3.
TDSTotal dissolved solids, mg/L. Above roughly 1 000 mg/L a softening bed is usually the wrong tool and demineralization is cheaper overall.
SilicaSiO2 in the feed, mg/L. Above 0.5 mg/L only strong base Type I resin removes it, and only when regenerated with warm caustic.
meq/L and mmol/LFor a monovalent ion, 1 meq/L equals 1 mmol/L. For calcium, 1 mmol/L equals 2 meq/L — check which unit the lab reported.
COACertificate of analysis — the batch-specific test report that accompanies a shipment: capacity, moisture, bead size, density, attrition.
SDSSafety data sheet, 16 sections in GHS format. Ion exchange resin is not regulated as dangerous goods for sea transport.
IMDGThe International Maritime Dangerous Goods code. Resin is not subject to it, which is why shipments move as general cargo.

Where to go next

From vocabulary to a decision

Units that catch people out

  • 1 meq/L = 50 mg/L as CaCO3
  • For calcium, 1 mmol/L = 2 meq/L
  • 1 mmol/mL = 1 eq/L = 1 000 eq/m³
  • 1 ppm ≈ 1 mg/L in dilute aqueous solution

Reviewed by the MAISEN technical team · last updated · corrections and additions welcome by email.

Next step

Send us the water analysis. We will send back the resin.

The same day is usually enough for a first recommendation with a price and a lead time. Tell us the application, the flow rate and the target quality — or paste the datasheet you are trying to match.

WhatsApp