Container loading from Xingang (Tianjin), Qingdao and Shanghai — Lianyungang, Jiangsu, China

Ion exchange resin calculator

Five numbers in, one sizing decision out: bed volume, run length, resin quantity, bag count and brine per regeneration. The formulas are printed underneath, so you can check the arithmetic yourself.

In one line: bed volume comes from flow and contact time (V = Q × EBCT); run length comes from bed volume, resin capacity and the ionic load (t = V × C ÷ (Q × ΔC)). Change any input below and both figures follow.

Your duty

Defaults are a sodium-cycle softener: 10 m³/h, 5 meq/L hardness, 6 min contact time, 001×7 at 1.9 eq/L. Softening usually runs at 2–6 min; take the figure from your design basis if you have one.

The answer

—Bed volume, m³
—Run length, h
—Resin mass, kg
—20 kg bags
—NaCl per regen, kg
—Water per cycle, m³
Send the analysis

Typical values only. The batch certificate is the number that counts, and real plants run 20–30 % shorter than the calculation.

The arithmetic

Two formulas, nothing hidden

If the calculator above is not loading, the same result comes out of these two lines with a pen.

1. Bed volume

V = Q × EBCT

V in m³, Q in m³/h, EBCT in hours. Softening 1–3 min (0.02–0.05 h), demineralization 2–5 min, mixed bed 1–2 min.

2. Run length

t = (V × C) ÷ (Q × ΔC)

C in eq/m³ (1.90 mmol/mL = 1 900 eq/m³), ΔC in eq/m³ — numerically the same as meq/L.

Assumptions behind the numbers

  • Brine at 1.3 × stoichiometric (100–150 g NaCl per litre of resin)
  • Wet bulk density 800 kg/m³, 20 kg per bag, 40 bags per pallet
  • No allowance for temperature, channeling or end-of-cycle kinetics — take 20–30 % off
  • Capacity is the volumetric figure from the batch certificate, not the dry gravimetric one

Worked examples

Three duties, three answers

The same two formulas, run on the duties that come up most often. Every figure below can be reproduced with the calculator above.

Blank cells only repeat the defaults: capacity 1.90 eq/L, density 800 kg/m³
DutyFlow m³/hLoad meq/L EBCT minCapacity eq/L Resin m³Run hNaCl kg
Softening, well water105.061.901.0038.0144
Demineralization, cation stage253.041.901.6742.2241
Mixed bed polish150.521.100.5073.342

Row 2 and 3 are not softeners: a demineralization train needs the cation and anion volumes added together, and a mixed bed is sized on the polish duty, not on the raw load.

Questions

Sizing questions buyers ask

How much resin do I need for a softener?

Size the bed from contact time first: bed volume in m³ equals flow in m³/h multiplied by empty bed contact time in hours. Softening usually runs at 1–3 minutes, so 10 m³/h with 2.5 minutes gives 0.42 m³ of resin. Then check the run length against capacity.

What contact time should I use?

Softening: 1–3 minutes. Demineralization: 2–5 minutes. Mixed beds: 1–2 minutes. Below these figures the bed breaks through early even though the capacity calculation looks fine.

What capacity figure should I put in?

Use the volumetric capacity from the batch certificate, not the dry gravimetric figure. A strong acid cation resin in sodium form is typically 1.8–2.0 mmol/mL; the same resin in hydrogen form is lower.

Why does my real run length come out shorter?

Kinetics, channeling, uneven flow distribution and the end of the cycle all cost time. Take 20–30 % off the calculated figure as a working plan, and treat the calculated number as the ceiling.

How much salt does one regeneration take?

For sodium-cycle softening, roughly 100–150 g of NaCl per litre of resin per cycle, which the calculator works out at 1.3 times the stoichiometric dose. Strong acid and strong base regeneration are similar in structure but use acid and caustic instead.

Does the calculator account for temperature?

Not directly. Cold water raises viscosity, slows kinetics and lowers practical capacity, so a bed sized at 25 °C will run shorter at 5 °C. If the feed is cold, add 10–20 % to the bed volume.

Back to the selection guide

Reviewed by the MAISEN technical team · last updated · corrections and additions welcome by email.

Next step

Send us the water analysis. We will send back the resin.

The same day is usually enough for a first recommendation with a price and a lead time. Tell us the application, the flow rate and the target quality — or paste the datasheet you are trying to match.