Ion exchange resin calculator
Five numbers in, one sizing decision out: bed volume, run length, resin quantity, bag count and brine per regeneration. The formulas are printed underneath, so you can check the arithmetic yourself.
In one line: bed volume comes from flow and contact time (V = Q × EBCT); run length comes from bed volume, resin capacity and the ionic load (t = V × C ÷ (Q × ΔC)). Change any input below and both figures follow.
Your duty
Defaults are a sodium-cycle softener: 10 m³/h, 5 meq/L hardness, 6 min contact time, 001×7 at 1.9 eq/L. Softening usually runs at 2–6 min; take the figure from your design basis if you have one.
The answer
Typical values only. The batch certificate is the number that counts, and real plants run 20–30 % shorter than the calculation.
The arithmetic
Two formulas, nothing hidden
If the calculator above is not loading, the same result comes out of these two lines with a pen.
1. Bed volume
V in m³, Q in m³/h, EBCT in hours. Softening 1–3 min (0.02–0.05 h), demineralization 2–5 min, mixed bed 1–2 min.
2. Run length
C in eq/m³ (1.90 mmol/mL = 1 900 eq/m³), ΔC in eq/m³ — numerically the same as meq/L.
Assumptions behind the numbers
- Brine at 1.3 × stoichiometric (100–150 g NaCl per litre of resin)
- Wet bulk density 800 kg/m³, 20 kg per bag, 40 bags per pallet
- No allowance for temperature, channeling or end-of-cycle kinetics — take 20–30 % off
- Capacity is the volumetric figure from the batch certificate, not the dry gravimetric one
Worked examples
Three duties, three answers
The same two formulas, run on the duties that come up most often. Every figure below can be reproduced with the calculator above.
| Duty | Flow m³/h | Load meq/L | EBCT min | Capacity eq/L | Resin m³ | Run h | NaCl kg |
|---|---|---|---|---|---|---|---|
| Softening, well water | 10 | 5.0 | 6 | 1.90 | 1.00 | 38.0 | 144 |
| Demineralization, cation stage | 25 | 3.0 | 4 | 1.90 | 1.67 | 42.2 | 241 |
| Mixed bed polish | 15 | 0.5 | 2 | 1.10 | 0.50 | 73.3 | 42 |
Row 2 and 3 are not softeners: a demineralization train needs the cation and anion volumes added together, and a mixed bed is sized on the polish duty, not on the raw load.
Questions
Sizing questions buyers ask
How much resin do I need for a softener?
Size the bed from contact time first: bed volume in m³ equals flow in m³/h multiplied by empty bed contact time in hours. Softening usually runs at 1–3 minutes, so 10 m³/h with 2.5 minutes gives 0.42 m³ of resin. Then check the run length against capacity.
What contact time should I use?
Softening: 1–3 minutes. Demineralization: 2–5 minutes. Mixed beds: 1–2 minutes. Below these figures the bed breaks through early even though the capacity calculation looks fine.
What capacity figure should I put in?
Use the volumetric capacity from the batch certificate, not the dry gravimetric figure. A strong acid cation resin in sodium form is typically 1.8–2.0 mmol/mL; the same resin in hydrogen form is lower.
Why does my real run length come out shorter?
Kinetics, channeling, uneven flow distribution and the end of the cycle all cost time. Take 20–30 % off the calculated figure as a working plan, and treat the calculated number as the ceiling.
How much salt does one regeneration take?
For sodium-cycle softening, roughly 100–150 g of NaCl per litre of resin per cycle, which the calculator works out at 1.3 times the stoichiometric dose. Strong acid and strong base regeneration are similar in structure but use acid and caustic instead.
Does the calculator account for temperature?
Not directly. Cold water raises viscosity, slows kinetics and lowers practical capacity, so a bed sized at 25 °C will run shorter at 5 °C. If the feed is cold, add 10–20 % to the bed volume.
Reviewed by the MAISEN technical team · last updated · corrections and additions welcome by email.